ASCO CO2 Gas Detectors are used to protect personnel wherever CO2 gas or dry ice is used in closed areas, for example during dry ice blasting or when producing dry ice. ASCO offers wallmounted solutions for area monitoring and portable devices for personal protection. ASCO CO2 Gas Detectors ensure continuous and automatic CO2 content measuring in the ambient air using infrared absorption measuring (NDIR). This technology is very troubleresistant to temperature variations or air draughts and therefore measures very accurately. The CO2 gas detectors are very simple to handle and all components are built splash proof.

  • Cooling and lubrication pumps
  • Gas Detector
  • Troubleresistant Temperature
  • Asco Detector

Product characteristics

Detector AGS Material box
plastic (IP54)
Detector AGS Voltage / Power supply / DC
9 - 32 VDC (12 – 32 VDC recommended), 2 A
Detector AGS Max power consumption
approx. 2 W
Detector AGS Relay preliminary alarm/alarm
below 2 A at 30 VDC or 250 VAC, SPDT
Detector AGS Analog output signal
4 - 20 mA
Sensor Material box
plastic (IP54)
Sensor Gas entry
diffusion
Sensor Measuring range
0 - 5 Vol. % CO2 (0 - 50.000 ppm)
Sensor Accuracy
0.1 Vol. % CO 2 (+ - 100 ppm or + - 5%)
Sensor Operating temperature
0 to +50 ° C
Detector AGP Alarm settings
3 thresholds
Detector AGP Alarm signals
audible, visual, vibrating
Detector AGP Dimensions
98 x 50 x 42 mm (3.9 x 2.0 x 1.7 in)
Detector AGP Weight
approx. 0.14 kg (0.3 lb)
Detector AGP Material
plastic material (IP54)
Detector AGP Operating conditions
0° - 50°C
Detector AGP Warm up time
approx. 5 sec
Detector AGP Resolution
1ppm; 0.01 vol% CO 2
Detector AGP Accuracy
±40ppm / ±3% reading
Detector AGP Gas entry
diffusion
Detector AGP Measuring range
0-5 vol% CO2
Detector AGP Calibration interval
1 year
Detector AGP Calibration method
Nitrogen or ambient air