Guided radar measurement Time-of-Flight Levelflex FMP50

Description

Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance. Particularly in basic supply or storage applications as well as utility processes FMP50 is the best choice. Levelflex FMP50 guided radar is used for continuous level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Product characteristics

Measuring Principle
Guided radar
Characteristic / Application
Basic device; Rod probe, Rope probe; Integrated data memory, Factory precalibrated, Reliable measuri
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus); 4-wire (HART)
Accuracy
Rod probe: +/- 2 mm (0.08 in); Rope probe: +/- 2 mm (0.08 in)
Ambient temperature
-40...+80 °C; (-40...+176 °F)
Process temperature
-20...+80 °C; (-4...+176 °F)
Process pressure absolute / max. overpressure limit
Vacuum...6 bar,; (Vacuum...87 psi)
Main wetted parts
Rod probe: 316L, PPS, Viton; Rope probe: 316, PPS, Viton
Process connection
Thread:; G 3/4, MNPT 3/4; Flange:; UNI Flange
Sensor length
Rod probe: 4 m (13 ft); Rope probe: 12 m (40 ft)

Domain icon Manufacturer/ Producer

4153 Reinach Bl - Switzerland

Contact

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free