SEMIN - fabricant plâtre enduits colles pour plâtriers peintres

France

Factory icon Manufacturer/ Producer

SEMIN
Web icon
49 Products

France

Verified by Europages

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018 Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.

Request for a quote

France

Verified by Europages

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1 : +A1 : 2018 Fire dampers EI 90 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 90. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.

Request for a quote

France

Verified by Europages

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboard Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018 Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.

Request for a quote

France

Verified by Europages

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1 : +A1 : 2018 Fire dampers EI 30 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 30. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.

Request for a quote

France

Verified by Europages

Door for technical ducts - White lacquered RAL 9016. - Non-detachable leaf - Left or right hand installation - Leaf with fire protection SOFTLINE 60 minutes fire resistant inspection hatches are specially designed to be integrated into the walls of technical ducts with a minimum thickness of 25 mm and meet the requirements of fire resistance class EI 60. They provide protection or an obstacle to the spread of fire from a room into the duct. The metal surface of the powder-coated frame hides the opening in the wall, providing a harmonious appearance. The lockable square key lock prevents opening by unauthorized persons. CSTB certified, PV No. RS-19-067. Customized dimensions on request within the maximum dimension allowed by the PV. Sizes: 2 plates of 12.5mm - Certificate EI 60 200x200 300x300 400x400 500x500 600x600

Request for a quote

France

Verified by Europages

Frame made of aluminium profile bars connected by "Tox" connections - Intumescent gas, smoke and flame tight seal in case of fire - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards - Quick and easy installation The 60-minute ceiling fire dampers are designed for installation in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against fire progression from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms. The safety catching arms ensure that the lid is intercepted every time the hatch is opened. The lid is easy to remove and replace.

Request for a quote

France

Verified by Europages

Cost-effective solution for fire-protected shaft walls - With peripheral lip seal (silicone) against smoke penetration - Quick and easy installation. Fire resistance on duct side and room side NF EN 1634-1 : +A1 : 2018 The inspection hatch is specially designed for installation on technical ducts with one of the requirements "external and internal heat load of the duct" and a fire resistance class EI 30. It offers a safe protection against the spread of fire from a room into the duct or counteracts it. The aluminium mounting frame is equipped with a fire protection strip. The cover of the inspection hatch is filled with DF fire protection plates and protected against the passage of smoke by a four-sided circumferential seal. The cover is secured on both sides by self-adjusting safety arms. These safety arms ensure that the cover stops every time the door is opened. The cover can be easily removed and replaced

Request for a quote

France

Verified by Europages

TECHNICAL DEFINITION Ready-to-use surface filler paste for filling interior holes and cracks. COMPOSITION AND APPEARANCE Water, calcium carbonate, sand, resin and various additives. SUITABLE SUBSTRATES All types of interior substrates : concrete, cellular concrete, cement, breeze block, brick, plasterboard, plaster tiles, plaster, old paint. COVERING Primer coat, smooth surface filler, wall coverings, paint REFERENCE DOCUMENTS • Filler meets EN 16566 standard • DTU 59.1 : Paint work TECHNICAL CHARACTERISTICS • Density : 1.5 • Dry extract : 82 % STORAGE 9 months in original unopened packaging away from frost and high temperatures. PREPARATION OF SUBSTRATES Substrates must comply with the DTU 59.1 standard i.e. be dry, clean, dust-free, hard and free of any trace of separating agent. APPLICATION Applied by hand using a filling knife or spatula. The thickness is 2 cm; to fill deeper holes, build up the filler in several steps The maximum thickness will be 1 cm per coat.

Request for a quote

France

Verified by Europages

TECHNICAL DEFINITION White, matt, ready-to-use thin finishing plaster to level interior substrates. Ideal plaster for renovating uneven or textured substrates. COMPOSITION AND APPEARANCE Water, calcium carbonate, resin and various additives. SUITABLE SUBSTRATES All types of interior substrates: concrete, cellular concrete, cement, breeze, brick, plasterboard, plaster tiles, plaster, old paint, glass canvas, old droplets, glass fibre cloth, old droplets. TECHNICAL PROPERTIES • Density : 1.3 • Dry extract : 66% • Fire classification : A2s1d0 STORAGE 18 months in original unopened packaging away from frost and high temperatures. APPLICATION Manual application : with a trowel or filling knife. Mechanical application : airless spray, spraying machine. In cold weather, mix the product quickly to aid aspiration. We recommend removing the filter from the pump, spraying at about 60 cm from the substrate.

Request for a quote

France

Verified by Europages

TECHNICAL DEFINITION Interior finishing plaster. Can be used with Airless spray. It provides a fine, uniform and even finish and is easy to sand. COMPOSITION AND APPEARANCE Water, calcium carbonate, resin and various additives. The resulting paste is off-white in colour. COVERINGS Primer coat, paint, wall coverings. TECHNICAL PROPERTIES • Density : 1.8 • Dry extract : 73% STORAGE 18 months in original unopened packaging away from frost and high temperatures. PREPARATION OF SUBSTRATES. Substrates must comply with the DTU 59.1 standard i.e. be dry, clean, dust-free, hard and free of any trace of separating agent. Scrape, brush and remove dust from concrete, plasterboard and plaster tiles. APPLICATION Manual application : With a trowel or filling knife. Mechanical application : Airless and spraying machine. In cold weather, mix the product quickly to aid aspiration. We recommend removing the filter from the pump, spraying at about 80 cm from the substrate.

Request for a quote

Domain icon Manufacturer/ Producer

SEMIN

1 rue de La Gare

57920 Kedange-Sur-Canner - France

VAT No.
Contact