Safety relays with forcibly guided contacts

OA 5642
Web icon

Description

• According to DIN EN 61810-1, DIN EN 61810-3, DIN EN 45545 (fire protection on railway vehicles) • With forcibly guided contacts • Safe separation betwenn coil/contact and contact/contact for applications at pollution degree 2 with rated insulation voltage 250 V • Clearance and creepage distances contact - coil ≥ 5.5 mm contact - contact ≥ 5.5 mm • Low nominal and holding power • High mechanical service life • Extremly smallest height only 10.3 mm and minimum area • RoHS compliance • Placing SMD components between PCB and relay is possible

Product characteristics

Function
Safety relays
Type of relay
monostabil
Contact material
AgSnO2; AgNi
Continuous current
8 A
Nominal voltage UN DC
6 - 110 V
Voltage Range UN
0,7 - 1,6 V
Test voltage (AC) contact set - coil
≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥
5,5 mm
Temperature range (- / +)
40 - 85 °C
Protection type
RT III (wash-tight)
Size L x W x H
26,6 x 25 x 10,3 mm
Approvals
TÜV; cRUus
Relay type
OA 5642

Documents

Domain icon Manufacturer/ Producer