Safety relays with forcibly guided contacts

OA 5667/_____4
Web icon

Description

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • Clearance and creepage distances: contact - coil ≥ 8 mm contact - contact ≥ 5,5 mm Double and reinforced insulation between contacts • Low rated power consumption • High voltage resistance ≥ 4 kV at contamination level 2 • High mechanical service life • Compact size, small height

Product characteristics

Function
Safety relays, reinforc. insulation
Type of relay
monostabil
Contact material
AgSnO2; AgNi
Continuous current
6 A
Nominal voltage UN DC
6 - 110 V
Voltage Range UN
0,75 - 1,3 V
Test voltage (AC) contact set - coil
≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥
8 mm
Temperature range (- / +)
40 - 85 °C
Type according to DIN EN 61810-3
A/B
Protection type
RT II (flux-proof relay)
Size L x W x H
27 x 25 x 10,8 mm
Approvals
TÜV; cRUus
Relay type
OA 5667/_____4

Documents

Domain icon Manufacturer/ Producer

78120 Furtwangen - Germany

Contact