• Acc. to DIN EN 61810-1, DIN EN 61810-3, DIN EN 50578 (UIC 736) • With forcibly guided contacts • High switching reliability due to crown contacts • Clearance and creepage distances: contact - coil ≥ 8 mm contact - contact ≥ 5.5 mm Double and reinforced insulation with pollution degree 2 Overvoltage category: III • High voltage resistance ≥ 4 kV • High mechanical service life • High temperature range: - 40 ... + 75°C • High continiuous thermal current Ith = 10 A

Product characteristics

Function
Safety relays, according DIN EN 50578
Type of relay
monostabil
Contact material
AgSnO2; AgNi
Continuous current
10 A
Nominal voltage UN DC
6 - 110 V
Voltage Range UN
0,75 - 1,4 V
Test voltage (AC) contact set - coil
≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥
8 mm
Temperature range (- / +)
40 - 75 °C
Protection type
optional RT III (wash-tight); RT II (flux-proof relay)
Size L x W x H
77,1 x 20 x 39,5 mm
Approvals
TÜV
Relay type
OA 5603/39__L1

Documents