The mechanical counterflow cooler for pellet is designed to cool hot pellets by means of a counter-flow stream of cool air which enters the cooler chamber from the bottom through the inlet at the bottom of the device and leaves it through the outlet located at the top of the cooler. An corresponding layer of material is maintained in the cooling chamber which is fed through an inlet sluice located in the upper part of the cooling chamber. When the maximum filling level in the cooler is reached, the sensor activates the discharge grate, which cyclically discharges the cooled product into the discharge hopper until the rated minimum level is reached. The minimum and maximum fill levels in the cooler chamber is regulated by manually adjusting the position of the fill sensors. In the lower part of the cooler, there is a discharge mechanism which ensures even removal of material from the cooler chamber.

  • Automation - systems and equipment
  • Mechanical counterflow cooler
  • For pellet
  • Cooling of hot pellets

Product characteristics

Model/Type
VK-RP
Material
structural steel, stainless steel
Discharge mechanism
inlet valve, adjustable system for uniform layer of material
Inlet valve type
gear
Capacity
2.5 – 25 t/h
Manufacturer
Geelen
Overlay
paint, spray painting
Cooler chamber
inspection holes, filling level sensors, fire safety systems
Discharge system
triple movable grit