SICHUAN ODOT AUTOMATION - Leading automation data acquisition solutions provider

China

Factory icon Manufacturer/ Producer

SICHUAN ODOT AUTOMATION
Web icon
51 Products

China

Verified by Europages

CT-5720 Bus extended slave module Module Description The bus extened slave module is used to extend the bus.The bus extended slave module has no process data and configuration parameters.

Request for a quote

China

Verified by Europages

Terminal modules are used to stabilize the internal bus communication. When the number of adapter extension IO modules reaches 16 or more and terminal modules should be required. When the number of adapter extending IO modules is less than 16, and the terminal module CT-5810 only for dustproof could be selected. The dustproof terminal could cover the internal bus and field power supply hardware of the last IO module. And terminal modules have no process data and configuration parameters.

Request for a quote

China

Verified by Europages

IO Config V1.0.0.6(Fully with .NET4.0.rar|CT-7221CT-7221 Power Supply Extension Module 5V/2A Module features System Power and Field Power Extension System Power Output 2A@5VDC Field Power Extension 8A Current

Request for a quote

China

Verified by Europages

CN-8031 Modbus TCP Network Adapter supports the standard Modbus TCP Server Communication, and Ethernet supports the cascade function of dual-port switches.This adapter supports access to 5 Modbus TCP clients simultaneously, supports Modbus function code 01/02/03/04/05/06/15/16 /23, supports the Modbus application of watchdog, supports the process data maximum sum of input and output of 8192 bytes, and supports number of the extension IO module of 32. Module carries with the diagnostic function and it could monitor the communication status of IO module in real time.

Request for a quote

China

Verified by Europages

IO Config V1.0.0.6(Fully with .NET4.0.rar|CT-3804 CT-4234: 4-channel analog output /0&4-20mA/16-bit single-terminal Module features 2 output ranges can be set(0-20mA、4-20mA) The module internal bus and field output adopts magnetic insulation Single-terminal grounded together output mode

Request for a quote

China

Verified by Europages

CT-3238: 8-channel analog input /0&4-20mA/15-bit single-terminal Module features The module supports 8-channel current signal acquisition. The module can be configured for 0-20mA or 4-20mA current signal acquisition. The module supports 2-wire (non-loop output, external power supply required) or 4-wire current sensor input. The internal bus of the module and field input adopts magnetic insulation. The module input channel is connected to the field active analog signal current output sensor. The module channel equips with TVS overvoltage protection

Request for a quote

China

Verified by Europages

ODOT B series integrated I/O module consists of communication board (COMM board) module and extended IO module. The COMM board could select the corresponding bus module according to the communication interface of the controller system. The mainstream industrial communication protocols include Modbus, Profibus-DP, Profinet, EtherCAT, EtherNet/IP, CANopen, CC-Link, PowerLink, etc. The extended I/O module is divided into six categories: digital input module, digital output module, analog input module, analog output module, special module, and hybrid I/O module. The COMM board and extended IO modules could be freely combined based on site requirements. The integrated IO module could lower the cost when there are few data points.

Request for a quote

China

Verified by Europages

This is a converter developed by Sichuan Odot Automation System Co., LTD between RS232/485/422 and TCP/UDP.This protocol converter can easily connect serial port devices to Ethernet and realize network upgrade of serial port devices. Protocol converter supports the function of "data transmission", which can be set as a client or a server. This function can easily realize the data communication between PLC, server and other Ethernet devices and the underlying serial port devices. Modules that support this feature are ODOT-S1E1 and ODOT-S2E1.

Request for a quote

China

Verified by Europages

AI0B0X Series Integrated IO AIOBOX-16/32 Al0BOX-16 supports single-deck mother board, 3 slots, slot 0 for communication adaptor, slot 1/2 for I/O module, Al0BOX-32 supports double-deck mother board, 5 slots, slot 0 for communication adaptor, slot 1/2/3/4 for I/O module Al0BOX-16 supports single-deck mother board, 3 slots, slot 0 for communication adaptor, slot 1/2 for I/O module; Al0BOX-32 supports double-deck mother board, 5 slots, slot 0 for communication adaptor, slot 1/2/3/4 for I/O module ; Slot 0 can be Modbus-TCP/Modbus RTU, PROFINET, EtherCAT, PROFIBUS-DP and CANopen; Slot 1/2/3/4 can be selected according to customer needs, Max. 32 channels;

Request for a quote

China

Verified by Europages

AIOBOX-MT124F supports 16-channel DI, supports source and sink two-way Input, input voltage 24v/0v. AIOBOX-MT222F supports 16-channel DO, high-level voltage is valid, output voltage 24v. AIOBOX-MT623F supports 8-channel DI, supports source and sink two-way input, input voltage 24v/0v. AIOBOX-MT623F supports 8-channel DO, high-level voltage is valid, output voltage 24v. LED indicators for 16 channel input & output. Two or three-wire digital sensor can be connected through input channel. 32-bit counter is supported by every input channel (frequency: <200Hz). Thermal shutoff and overcurrent protection. The bus inside the module and the field input are isolated by optical coupler.

Request for a quote

Domain icon Manufacturer/ Producer

SICHUAN ODOT AUTOMATION

Plant Building No. 204COMPREHENSIVE BONDED ZONE

Eastern section of feiyun avenue, mianyang city

621000 Sichuan Province - China

Contact