• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • flame arrester

Results for

Flame arrester - Import export

Germany

For installation into pipes to the protection of vessels and components against deflagration of flammable liquids and gases. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Bi-directionally working in pipes, whereby an operating pressure of 1.2 bar abs. and an operating temperature of 60 °C must not be exceeded. The distance between a potential ignition source and the flame arrester must not exceed 50 times the inner pipe diameter. The installation of the Deflagration flame arrester into horizontal and vertical pipes is permissible. When equipped with one or two temperature sensors, the devices are protected under atmospheric conditions against a short time burning by a burning time tBT = 1.0 min. If only one temperature sensor, then it is to be placed on the device side where a burning could be expected.

Request for a quote

Germany

Installation into pipelines as inline detonation flame arrester e. g. for the protection of ignition gas lines or measuring devices. Applicable for all materials of the explosion groups IIA1 up to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Operating from both sides, for a maximum operating pressure of 1.2 bar abs. and a maximum operating temperature of 60 °C.

Request for a quote

Germany

Application as end-of-line armature for venting and breathing of tanks. Tested and approved against atmospheric deflagrations for all materials of the explosion group IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm and a maximum operating temperature of 60 °C. Vertical mounting (for tank roofs) with an integrated elbow as an option.

Request for a quote

Germany

Application as end-of-line armature for venting apertures on tank installations, valve is explosion-proof and endurance-burning proof for certain inflammable liquids. Used mainly as venting and breather device for fixed roof tanks to prevent inadmissible pressure and vacuum and to minimize unwelcome gas losses and inadmissible emissions. Approved for all materials of the explosion group IIA with a maximum experimental safe gap (MESG) > 0.9 and a maximum operating temperature of 60 °C. The housing is mounted perpendicularly on a tank roof. If required by the customer, the valve is equipped with an explosion-proof condensate drain device.

Request for a quote

Germany

For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Bi-directionally working in pipes, whereby an operating pressure of 1.2 bar abs. and an operating temperature of 60 °C must not be exceeded. The installation of the detonation flame arrester into horizontal and vertical pipes is permissible. Provided with one or two temperature sensors (PT 100) the armature is certified against short time burning from one or both sides. If only one thermal sensor is attached, it must be installed into that part of the body from which a fire is expected.

Request for a quote

Germany

For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Bi-directionally working in pipes, whereby an operating pressure of 1.2 bar abs. and an operating temperature of 60 °C must not be exceeded. All sizes are tested against “stabilized burning” and withstand this up to a max. burn time BT ≤ 30.0 min. To detect a “stabilized burning” a temperature sensor must be installed at each endangered side. Mounting is acceptable in any position, in horizontal as well as in vertical pipes.

Request for a quote

Germany

For installation into pipes to the protection of vessels and components against deflagration of flammable liquids and gases. Approved for all substances of explosion group IIA1 (old: I) with a maximum experimental safe gap (MESG) ≥ 1.14 mm. Bi-directionally working in pipes, whereby an operating pressure of 1.2 bar abs. and an operating temperature of 60 °C must not be exceeded. The distance between a potential ignition source and the flame arrester must not exceed 50 times the inner pipe diameter. An installation into horizontal and vertical pipes is permissible. To detect a thermal load on the KITO® flame arrester element in operation a temperature sensor can be implemented as an option into the flame arrester body. Proof against “stabilized burning” and withstand this up to a max. burn time BT = 1.0 min.

Request for a quote

Germany

Proof for products of explosion group IIA with a maximum experimental safe gap (MESG) > 0.9 mm and a maximum operating temperature of 60 °C. Mainly used as equipment of fixed roof tanks for venting and inbreathing to prevent undue pressure resp. vacuum and undesired losses of vaporization, respectively undue emissions. Installation on top of storage vessels. Available with an explosion and endurance burning proofed condensate drain device.

Request for a quote

Germany

Application as installation explosion-proof and endurance burning proof for certain flammable liquids of the explosion group IIA with a maximum experimental safe gap (MESG) > 0.9 mm and a maximum operating temperature of 60 °C. As venting and breather device for fixed roof tanks to prevent inadmissible pressure and vacuum and to minimize gas losses by variable pressure setting of the weight-loaded and/or spring-loaded valve devices. Installation of an explosion-proof condensate drain device is possible.

Request for a quote

Germany

Application as end-of-line armature for venting apertures on tank installations. Tested and approved against atmospheric deflagrations for all materials of the explosion group IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm and a maximum operating temperature of 60 °C. Used mainly as venting and breather device for fixed roof tanks. Used to prevent inadmissible pressure and vacuum and to minimize unwelcome gas losses or inadmissible emissions respectively. The housing is mounted perpendicularly on a tank roof. Available with an explosion and endurance burning proofed condensate drain device.

Request for a quote

Germany

Application as breather/venting safety device incorporating an explosion proof flame arrester element for installation on top of storage tanks, tank access covers or breather pipes. The breather allows the unimpeded flow of gases out to atmosphere and air into the tank/pipe thereby preventing vacuum locks whilst ensuring provision of a permanent and reliable protection against any flashback into the tank/pipe. This device is not permitted to be installed in enclosed areas. Approved for all materials of the explosion group IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm and a maximum operating temperature of 60 °C .

Request for a quote

United Kingdom

Pyroprotect is a Class B-s1,d0 flame retardant impregnant for exterior use. This waterborne, transparent coating helps to prevent mould, rot, mildew and fungi as well as offering class-leading fire protection. Pyroprotect is a flame retardant impregnant for wood with excellent weather resistance properties. Suitable for processing new and wood preservative-treated wooden surfaces, not suitable for surfaces treated with film-forming coatings (lacquers, paints, oils). Pyroprotect is used extensively in rail applications where timber sleepers are exposed to flammable liquids, debris and then sparks from power rails. Pyroprotect is applied at ambient temperature by brush, roller or spray applied there is no requirement for heat treatment or specialist pressure treatment. Surfaces are flame retardant 5 days post coating. Additional Information: Class B1 D0 S1 flame retardant VOC free.

Request for a quote

Germany

Verified by Europages

With flexible edge extraction. Operation selectable: left, right or both sides. 2 sockets on each side – 2 x 230 V and 2 x 400 V. With consistently welded niche for two or three Multi-Line 65 devices (on-site). Mobile on 4 castors (2 lockable). Incl. front sided glass splash guard, extensions with cutouts on both sides and GN-insets. Vapors are extracted on three sides and passed through the patented ACS – circulating air system. High performance grease separators (100 % flame arresting) are installed in left and right side walls along with two removable grease collection trays. The substructure contains low-noise radial fans. Cleaning odors with patented plasma technology in combination with activated charcoal filters. The ACS meets the requirements of VDI 2052 and is TÜV-certified to DIN EN 60335. Furthermore all components meet DIN, VDE, GS and TÜV.

Request for a quote

Austria

Verified by Europages

Our core business is the most up-to-date quality gas flare technology for a safe, efficient and environmentally friendly combustion of gases from landfill, bio and sewage gas systems. Our fully automatic flare NOXmatic with its extensive range of accessories can be suited for every low and medium temperature combustion application. With various burner systems we can cover the complete spectrum of power requirements in single or multi-stage operation. The NOXmatic flare is manufactured entirely from stainless steel and equipped with high quality components (i.e., ATEX certified flame arresters, DVGW certified automatic and manual valves...). All control and monitoring functions are achieved with an individual programmable controller, which also governs the signal transfer with the main controller. NOXmatic flares can be delivered worldwide with a capacity from 100kW to 20MW.

Germany

As breather/venting safety device incorporating an explosion proof flame arrester element for installation on top of storage tanks, tank access covers or breather pipes. The breather allows the unimpeded flow of gases out to atmosphere and air into the tank/pipe thereby preventing vacuum locks whilst ensuring provision of a permanent and reliable protection against any flashback into the tank/pipe. This device is not permitted to be installed in enclosed areas. Approved for all materials of the explosion group IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 and an maximum operating temperature of 60 °C.

Request for a quote

Germany

For installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Working unidirectional in pipes, whereby an operating pressure of 1.2 bar abs. and an maximum operating temperature of 60 °C must not be exceeded. Provided with one temperature sensor (PT 100) the armature is certified against short time burning from one side. The installation is not dependent on the position and both directions of flow are possible. During installation, please observe the direction of detonation and the indication „protected side“.

Request for a quote

Germany

As end-of-line armature, for venting apertures on tank installations. Used mainly as venting and breather device for fixed roof tanks. Used to prevent inadmissible pressure and vacuum and to minimize unwelcome gas losses or inadmissible emissions respectively. The housing is mounted perpendicularly on a tank roof. The product vapours can be discharged through a collective line into the atmosphere connected to the line flange on the pressure side.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Explosion proof safety valve to protect inbreathing openings of storage tanks, vessels and pipes to prevent inordinate vacuum. Approved for flammable liquids of explosion group IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm and a Maximum operating temperature of 60 °C.

Request for a quote

Germany

As breather/venting safety device incorporating an explosion proof flame arrester element for installation on top of storage tanks, tank access covers or breather pipes. The breather allows the unimpeded flow of gases out to atmosphere and air into the tank/pipe thereby preventing vacuum locks whilst ensuring provision of a permanent and reliable protection against any flashback into the tank/pipe. This device is not permitted to be installed in enclosed areas. Approved for all materials of the explosion group IIB3 with a maximum experi-mental safe gap (MESG) ≥ 0.65 mm and an maximum operating temperature of 60 °C .

Request for a quote