Hybymed® IBPM plus system is an upgrade to the hybymed® IBPM system because it additionally enables closed blood sampling system. Waste of all types and the possibility of IV line and subsequently patient infection are reduced, and medical personnel are protected from direct blood contact.Closed, needleless, “in line” clean arterial blood sampling system. Part of the invasive arterial blood pressure measurement line. Standardises the blood sampling procedure from the aspects of repeatability, accuracy, and safety. Prevents bubble formation during the taking of samples. Simple wash-out of blood residuum.
Request for a quoteSlovenia
Compatible with the ANSI/AAMI BP22 and IEC 60601-2-34 standards.SI/AAMI BP22 in IEC 60601-2-34 Calibrated and stabilised regarding sensitivity, linearity, and the zero point. Sensitivity: 5 μV/V/mmHg ± 2% Zero drift: less than ±1.0 mmHg/8 h “Click-on” or sliding housing design Sensor with direct contacts, wireless Wide array of accessories for easier use Colour-coded to minimise incorrect connections In combination with valves and/or rinsing system
Request for a quoteSlovenia
The contact plate enables physical attachment of sensors, collects signals from all sensors, and forwards this information to the monitor via a single cable. The standard variants enable the connection of two to four sensors. We attach the contact plates to the bed frame, wheelchair, or the stands with holders. Due to the multitude of variants, cables with connectors, which connect the contact plate with the patient’s monitor, are always manufactured according to the final user’s specifications.
Request for a quoteSlovenia
These are simply mechanical devices with which we fix the contact boards to a bed, a stand, etc. There are several standard models with zero to four degrees of freedom.
Request for a quoteSlovenia
The CBSS holder is a specific add-on that may be attached to any hybymed® contact board. It serves as a CBSS reservoir holder. This enables simple access and single-hand work with the CBSS reservoir.
Request for a quoteSlovenia
The cables connect the contact board to the monitor or directly or via an intermediate standardised connector; the selection depends on the final user. More than 100 different cables are available, because the monitors use a wide array of connectors.
Request for a quoteSlovenia
Closed, needleless, “in-line” system Standardises the blood sampling procedure from the aspects of repeatability, accuracy, and safety. Part of the invasive arterial blood pressure measurement line. Prevents bubble formation. Enables single-hand manipulation. Reduces blood loss from sampling. Minimises the IV line infection risk. Compatible with the CBSS holder. Customisation for the final user comprises typical volume, connection tube diameter, and interface to the holder.
Request for a quoteGermany
CNC machining parts, CNC turning parts, CNC milling parts,Aluminium Housing, Flange, Valve Seat, Bush, Sleeve, Mechanical Parts for electronic devices,Mechanical Engineering Service, stamping parts, sheet metal parts, Cnc machining parts from China, Anodized Aluminium Milling part, Stainless Steel shaft, Titanium mechanical parts, Aluminium Enclosure, Aluminium turned lens in black anodize finish,stainless steel valve, copper machined plate, brass bush, brass sleeve, brass nut in nickel plated,copper screws, red anodized aluminium holder, blue anodized aluminium CNC milling plate, anodized mechanical parts, copper gold plating handle, zinc plated screws, custom made CNC turned part,ShenZhen mechanical parts supplier, critical cnc machining parts, precision mechanical parts, mechanical parts for camera, Stainless steel high polishing part, pump and valve mechanical accessories, Optic mechanical products, High quality precision machining parts, Nitrating steel shaft,machined mechanical p
Request for a quoteUnited Kingdom
Knight Optical can offer Barium Fluoride Windows for use within Medical Imaging. We supply a range of barium fluoride windows for a range of applications. All individually QA checked and metrology tested for quality to ensure parts meet customer specification. Supplied in a range of sizes and shapes with custom coatings tailored to meet your individual applications. Knight Optical supply precision optical components to customers in the medical industry for applications such as medical thermology and thermography. Barium fluoride optics are used in the detection and screening of breast cancer and for screening for atypical pneumonia (SARS) and monitoring respiratory conditions. Due to barium fluoride’s high radiation resistance, it is ideal for use in high radiation (x-ray/gamma rays) environments. Other applications include cryogenically cooled thermal imaging systems, infrared spectroscopy and high energy neutron detection. Read PDF for more information…
Request for a quoteUnited Kingdom
Knight Optical can offer you Custom Sapphire Cylindrical Lenses, for use within Endoscopes. We supply a range of Sapphire options for a variety of applications – all individually QA checked and metrology tested for quality to ensure parts meet customers’ specifications. What’re more, our Sapphire Cylindrical Lenses are supplied in a range of sizes and shapes with custom coatings tailored to meet your individual applications. Sapphire (Al2O3) is one of the hardest minerals and optical materials available for use in the range from UV up to 5µm, making it ideal as a protective window for camera systems. Cylindrical lenses are designed to focus light into a straight line, rather than to a single point. As the name suggests, the lens surface has a cylindrical shape rather than the usual spherical formation, which allows for one-dimensional shaping of light along a line. Cylindrical lenses are often used to change the profile of laser beams; for example Read PDF for more info
Request for a quoteUnited Kingdom
Knight Optical can offer Littrow Prisms for use within Laser Applications. We supply a range of Littrow Prisms for a range of applications. All individually QA checked and metrology tested for quality to ensure parts meet customer specification. Supplied in a range of sizes and shapes with custom coatings tailored to meet your individual applications. Knight Optical supply precision optical components to customers within Laser Applications. Littrow Prisms are used near the end of an optical cavity of a laser system to finely adjust the output frequency by changing the AOI of the prism. For more information read PDF …
Request for a quoteCreate one request and get multiple quotes form verified suppliers.