Georgia
Manufacturer/ Producer
Georgia
The aluminum cores with section 2,5-50mm2 inclusive are made of single wire with 1st class flexibility, 70-240mm2 inclusive with twisted multi-core wires with 2 class flexibility, according to Gost standard 22483-77. Number of cores in the cable 1,2,3,4,5The insulated cores are made of different colors, an inscription is made on the cover of the conductor “JSC Sakcable” cable brand, year of production. Labelling of cores with colors or figures 0,1,2,3,4.
Request for a quoteGeorgia
For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For stretching in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forcesThe aluminum cores with section 2,5-25mm2 inclusive are produced of single wire of 1 class flexibility according to Gost standard 22483-2012. Number of cores in the cable 2,3.The aluminum cores with section 2,5-25mm2 inclusive are produced of single wire of 1 class flexibility according to Gost standard 22483-2012. Number of cores in the cable 2,3.
Request for a quoteGeorgia
For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For stretching in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forces. While laying the cables together, they are flame retardantThe copper cores with cross section 1,5-6mm2 inclusive are produced with 1 class flexibility,10-240mm2 are produced with twisted multi-core 2 calass flexibility according to standard 22483-2012. Number of cores in the cable 1,2,3,4,5.
Request for a quoteGeorgia
For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For stretching in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forces. While laying the cables in a single layer, they are flame retardantThe copper cores with section 2,5-25mm2 inclusive are produced of single wire of 1 class flexibility, accorgind to gost standard 22483-2012. Number of cores in the cable 2,3.in case of supply in bundles the construction length is agreed with the customer. On wooden drum no less than 450m. One batch can contain no more than 20% of cable length not less than 50m.
Request for a quoteGeorgia
For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For straining in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forcesThe copper cores with section 1,5-6mm2 inclusive are produced of single wire of 1 class flexibility, 10-240mm2 inclusive with twisted multi-core wires of 2 class flexibility, according to standard IEC 60228:2004. Number of cores in the cable 1,2,3,4,52,5-16mm2-450m; 25-70mm2-300m; 95-240mm2-200min case of supply in bundles the construction length is agreed with the customer. In case of agreement with the customer cables of different construction lengths can be produced
Request for a quoteGeorgia
For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For straining in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forcesInstallation temperature: -150C. The max. allowable core heating temperature in short circuit with duration of not more than 4 seconds must not be above 1600C The conductor is resistant to 98% relative air humidity under +350C conditions Conductive lobe for long-term allowable heating temperature +700CThe aluminum cores with section 2,5-50mm2 inclusive are produced with single wire of 1 class flexibility, 70-240mm2 inclusive with twisted multi-core wires of 2 class flexibility, according to standard 22483-77. Number of cores in the cable 1,2,3,4,5
Request for a quoteGeorgia
For laying in ground, open air, in concrete, inside buildings, in cable channels, in electrical stations, in industrial plants and in the commutation systems where there is no danger of mechanical damage of the cable. Because the permissible operating temperature of the conductor is + 90 0C. Core isolation (XLPE) polyethylene provides higher current loadThe aluminum cores with section 2,5-16mm2 inclusive are produced of single wire of 1 class flexibility, 25-240mm2 inclusive with twisted multi-core wires of 2 class flexibility, according to standard IEC 60228 : 2004. Number of cores in the cable 1,2,3,4,5.Label attached to wooden drum or bundle, or in case of request of the customer with inscription on top: “JSC Sakcable” cable brand, date of production. Labeling of conductive cores with colors or figures 0,1,2,3,4 with inscription on the top of insulated cores
Request for a quoteGeorgia
For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For laying in ground, for overhead, into the concrete, for laying into cable channels. Using in electrical stations, in industrial equipment and in commutation systems. Working temperature on the conductor +90 0C. While laying the cables in groups, they are flame retardantThe aluminum cores with section 2,5-50mm2 inclusive are produced with one wire of 1 class flexibility, 70-240mm2 inclusive with twisted multi-core wires 2 class flexibility, according to standard IEK60228 : 2004. According to customer requested, it’s possible to produce cross sections 16:50 with multi-core wires. Number of cores in the cable 1,2,3,4,5in case of supply in bundles the construction length is agreed with the customer. In case of agreement with the customer cables of different construction lengths can be produced
Request for a quoteGeorgia
Low-smoke, zero-halogen, flame-retardant power cable. For fixed indoor installation as well as in concrete, but not for direct burial in ground or application in waterThe aluminum cores with section 2,5-50mm2 inclusive are produced with one wire of 1 class flexibility, 70-240mm2 inclusive with twisted multi-core wires 2 class flexibility, according to standard IEK60228 : 2004. According to customer requested, it’s possible to produce cross sections 16:50 with multi-core wires. Number of cores in the cable 1,2,3,4,5in case of supply in bundles the construction length is agreed with the customer. In case of agreement with the customer cables of different construction lengths can be producedLabel attached to wooden drum or bundle, or in case of request of the customer with inscription on top: “JSC Sakcable” cable brand, date of production. Labeling of resistance cores with colors or with numbers
Request for a quoteGeorgia
For connecting automatic and semi-automatic devices of arc welding with source of currentConductor cores with section 16-70mm2 inclusive are produced with multiple twisted wire (120-396) of 5 class flexibility, according to standard 22483-2012not less than 100m In case of agreement with the customer cables of different construction lengths can be producedLabel attached to wooden drum or bundle, or in case of request of the customer with inscription on top: “JSC Sakcable” cable brand, date of production. Labeling of conductive cores with colors or figures 0,1,2,3,4 with inscription on the top of insulated cores
Request for a quoteNetherlands
Dutch Scrap Recycling B.V. Is the leading trader in Iron, Aluminium, copper, plastic, rubber , Paper, copper cathode scraps in the Netherlands and Continues to Be a Family Business With Four Generations Working to Innovate the Recycling Industry.
Request for a quoteChina
Charge all kinds of smart devices just with 1 cable. Short length avoides kontting. Big logo surface illuminates your brand with LED light.
Request for a quoteCreate one request and get multiple quotes form verified suppliers.