The STRATE AWALIFT 80 is the system preferred for draining single- and two-family homes where the drainpipe is below the backwater level (acc. to DIN 1986-100) and the houses cannot be drained using natural gradient. DIN EN 12056-4 specifies the backwater level here as being the road surface of the connection point to the public sewage system. The AWALIFT 80 was specially developed as a small system for building services engineering (max. 12 residents). This means that for the first time, demanding users now have a sewage pumping station available in patented and tried-and-trusted separator technology, which employs polymer components throughout. And the separator system effectively prevents pump blockage. Area of use Single-family homes (e.g. toilet, shower, bath, sink, washing machine etc.) Basement flats Party rooms in the basement Two-family homes etc. Product features Sewage Pumping Station AWALIFT 80 after DIN EN 12056-4 Suitable for faecal wastewater

Request for a quote

Germany

Verified by Europages

The STRATE AWALIFT 100 is the system preferred for draining storeys, houses and plots of land below the backwater level in accordance with DIN 1986-100, i.e. for properties that cannot be drained using natural gradient. DIN EN 12056-4 specifies the backwater level here as being the road surface of the connection point to the public sewage system. Single-family homes (e.g. toilet, shower, bath, sink, washing machine) Basement flat Party rooms in the basement Two-family homes Product features One tank with separator system One centrifugal pump and motor according to type and operating location required One non-return valve AWASTOP DN 100 K Level measurement Pump control type AWAmaster 1 1.5 m power supply cable, with CEE plug LGA certified according to DIN EN 12050-1 /. -4

Request for a quote

Germany

Verified by Europages

The STRATE AWALIFT 74/1 is used primarily for draining floors, multi-family buildings and properties above the backflow level in accordance with DIN 1986-100, e.g. for properties that cannot be drained via a natural slope. DIN EN12056-4 establishes the upper edge of the street at the connection point to the public sewer system as the backflow level. Two-family homes Facilities that cannot be drained using natural gradient As protection from backwater damage Product features One tank with separator system One centrifugal pump and motor according to type and operating location required One non-return valve AWASTOP DN 100 K Level measurement Pump control type AWAmaster 1 1.5 m power supply cable, with CEE plug LGA certified according to DIN EN 12050-1 /. -4

Request for a quote

Germany

Verified by Europages

The AWALIFT 0/1 requires a space of just 1200 mm x 1200 mm or d=1500 mm. Thanks to its unique design, it can be installed in even non-standard installation areas. A variety of available motor power levels make it suitable for use in a wide range of applications. Multi-family homes Facilities that cannot be drained using natural gradient As protection from backwater damage Product features One tank with separator system One centrifugal pump and motor according to type and operating location required One non-return valve AWASTOP DN 100 K Level measurement Pump control type AWAmaster 1 1.5 m power supply cable, with CEE plug LGA certified according to DIN EN 12050-1 /. -4

Request for a quote

Germany

Verified by Europages

The AWALIFT 74/2 double installation provides improved operational reliability, since the pumps alternate to pump waste water (which has already been separated from bulk materials) from the separator. Bulk materials are first pumped into the pressure line, then the line is flushed with pre-cleaned water from the tank. Multi-family homes Where the reserve pump has to guarantee fail-safe operation e.g. in restaurants and public buildings Facilities that cannot be drained using natural gradient As protection from backwater damage Infrastructure facilities such as airports, industrial parks, subway systems etc. Product features One tank with separator system Two centrifugal pumps and motors according to type and operating location required Two non-return valves AWASTOP DN 100 K Two pressure pipe gate valves DN 100 Level measurement LGA certified according to DIN EN 12050-1 /. -4

Request for a quote

Germany

Verified by Europages

The AWALIFT 0/2 double installation with proven STRATE system conforms to the requirements of DIN 1986-100 and DIN EN 12056-4. The installation forms a closed, gas and odor-tight system that fulfills the highest requirements for hygiene and safety. The system can also be installed directly in the basement; no excavation is required. If it is installed outdoors, however, using a STRATE AWALIFT shaft is recommended. Larger buildings, industrial companies, individual streets Where the reserve pump has to guarantee fail-safe operation e.g. in restaurants and public buildings Facilities that cannot be drained using natural gradient As protection from backwater damage Infrastructure facilities such as airports, industrial parks, subway systems etc. Product features One tank with two separator systems Two centrifugal pumps and motors according to type and operating location required Two non-return valves AWASTOP DN 100 K Two pressure pipe gate valves DN 100

Request for a quote

Germany

Verified by Europages

The AWALIFT 1/2 is used primarily in municipal applications for draining large properties. It is a fully automated, floodable sewage pumping system with a proven separator system for up to 750 EW. Alternating two pumps provides a high level of operational reliability. There is no need to provide reserve pumps. This system also has a gas and odor-tight tank, the surface of which is coated with high-quality corrosion protection. •Larger buildings, industrial companies, individual streets •Facilities that cannot be drained using natural gradient •As protection from backwater damage •Infrastructure facilities such as airports, industrial parks, subway systems etc. Product features One tank with two separator systems Two rotary pumps and motors according to type and operating location required Two non-return valves AWASTOP DN 100 K Y-pipe DN 100 Two pressure pipe gate valves DN 100 Level measurement LGA certified according to DIN EN 12050-1 /. -4

Request for a quote

Germany

Verified by Europages

The STRATE AWALIFT 1/2x2 is used in many applications that require small quantities of waste water to overcome a high discharge head. With a capacity of 15 m3/h, the system is suitable for up to 750 EW. The system can be adapted to your individual needs through the use of different motor variations. Drainage of small towns with up to about 750 residents that cannot be drained using natural gradient. Drainage with larger pumping heads and longer pressure pipes As an intermediate pumping station within a pressure drainage system Residential and industrial areas Towns Communities Infrastructure facilities such as airports, industrial parks, underground stations etc. Product features The tank with two separator systems Four centrifugal pumps ST (M)65/80, motors according to type and operating location required Four pump gate valves One Y-pipe Two STRATE non-return valves Two gate valves Level measurement LGA certified according to DIN EN 12050-1 /. -4

Request for a quote

Germany

Verified by Europages

The AWALIFT 1/2 penta offers lots of power while requiring very little space. The system is installed directly at the shaft wall; this configuration significantly reduces the required shaft diameter. In addition, the 1/2 penta offers our trusted separator system. The use of two pumps ensures a high level of operational reliability. Large system capacity despite small space requirements: The system is set up directly at the shaft wall This makes a small shaft diameter possible Larger buildings, industrial companies, individual streets Facilities that cannot be drained using natural gradient As protection from backwater damage Infrastructure facilities such as airports, industrial parks, underground stations etc. Product features One tank with two separator systems Two centrifugal pumps and motors according to type and operating location required Four pump gate valves Two non-return valves AWASTOP DN 100 K Y-pipe DN 100 Two pressure pipe gate valves DN 100

Request for a quote

Germany

Verified by Europages

Anywhere small quantities of wastewater need to overcome a high discharge head is the perfect application for the flattened version of the AWALIFT 2/2, with a shape that makes it a good space-saving option. It also offers our proven bulk materials collection system and is installed dry. The system controls are individually adjusted and installed in a switch cabinet outside of the shaft. Draining small towns with up to about 1700 residents which cannot be drained using natural gradient or as an intermediate pumping station within the context of a pressure drainage system Residential and industrial areas Towns Communities Infrastructure facilities such as airports, industrial parks, underground stations etc. Product features One holding tank with two separator systems Two centrifugal pumps and motors according to type and operating location required Four pump gate valves Two STRATE non-return valves Two pressure pipe gate valves DN 100 One Y-pipe DN 100