• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • lightning arresters

Results for

Lightning arresters - Import export

Germany

Germany

Verified by Europages

iglidur® F: Lightning arrester Extreme stiffening and hardening, besides being highly electrically conductive iglidur® F bearings can be used in dry operation only conditionally, but display full mechanical potentials with oil and fat lubrication. iglidur® F is available as cylindrical bearings and plain bearings with flange. Electrically conducting High compressive strength Good temperature resistance high pv-value Good chemical resistance

Request for a quote

Germany

Combination arrester, lightning current and surge arrester, type 1+2 • Protection level ≤ 1.5 kV • For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305) • Lightning current arresting capacity up to 100 kA (10/350), 3+NPE • Line following current quenching 50 kA Ipeak, arrester backup fuse to 315 A gL/gG • Fulfils the requirements of VDE-AR-N 4100 for use in pre-meter area • Encapsulated, non-extinguishing spark gap arrester for use in distributor housings Application: Industrial systems and buildings with external lightning protection of the highest class I to IV. Compact protection device

Request for a quote

Germany

Combination arrester, type 1+2, for mounting on 40 mm busbars, for TN-S and TT systems • Protection level ≤1.5 kV to protect the terminals • Lightning protection equipotential bonding according to VDE 0185-305 (IEC 62305) • Lightning current arresting capacity up to 100 kA (10/350) 3+NPE • Fulfils the requirements of VDE 0100-534 (IEC 60364-5-53) • Line follow current quenching up to 50 kA and max. backup fuse up to 315 A gL/gG • Spark gaps for use in the pre-meter area according to VDE-AR-N 4100 Application: Building with lightning protection or outside cable infeed.

Request for a quote

Germany

Completely pre-terminated and ready for connection, consisting of: 3x MCD 50-B: Coordinated lightning current arrester, type 1+2 to EN 61643-11 and 1x MCD 125-B/NPE: Coordinated N-PE spark gap, type 1+2 to EN 61643-11. For interface 0 to 2 (LPZ) in accordance with lightning protection zone concept to IEC 61312-1 and/or VDE 0185-305. • Lightning protection equipotential bonding to VDE 0185-305 (IEC 62305) • Lightning current arresting capacity to 50 kA (10/350) per pole and up to 125 kA (10/350) in total • Protection level < 1.7 kV allows device protection • Short-circuit resistance 10 kA, arrester backup fuse to 500 A gL/gG • Suitable for use in pre-meter area according to VDE-AR-N 4100 • Encapsulated, non-extinguishing spark gaps Application: Industrial systems and buildings with external lightning protection of the classes I to IV.

Request for a quote

Germany

Lightning current combination arrestor, type 1+2 • For lightning current equipotential bonding to VDE 0185-305 (IEC 62305) • Lightning current arresting capacity of 12.5 kA (10/350) per pole and up to 50 kA (10/350) in total • Modular, plug-in arrestor with cut-off unit and visual status display • Locking mechanism with vibration protection and voltage keying • Plastic to UL 94 V-0 • The remote signalling (FS) variants have a potential-free changeover contact for remote signalling Application: Lightning current equipotential bonding for buildings of class III and IV. * Complete = Plug-in arrester and base

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business