• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • water-heaters- domestic

Results for

Water-heaters- domestic - Import export

United Kingdom

United Kingdom

A new cylinder style thermal store with a separate cold section - it can be installed without a discharge if preferred. The store is open vented at atmospheric pressure. The mains hot water delivery is suitable for one bath plus one shower on an overnight (off peak) charge. Perfect for modern apartments or the all electric home, this hot water thermal store system gives you the benefits of mains pressure hot water. Designed with modern lifestyles in mind, installation is simple, maintenance is low and the unit is compact. The unit is fitted with a hot water control pack and two 3kw immersion heaters. The ETS 160 should be connected to low tariff supply and used during appropriate periods for maximum efficiency. The thermal store is made from stainless steel for long life and has been upgraded to 60mm insulation thickness to exceed Part L of the Building Regulations. The store is guaranteed for 10 years. The fitted components are guaranteed for 2 years.

Request for a quote

United Kingdom

Use these Advance Thermal Stores for the provision of fast, safe hot water provision throughout the house. The indirect pattern cylinder (TSiC) without the integrated feed and expansion tank has to be fed with a remote F and E tank but can be sited anywhere in the property. They have two coils, the lower one for heat input from a boiler, the higher one for mains fed hot water services. They can be used with sealed system boilers and heating circuits on Y plan systems. These low maintenance pre plumbed units provide flow rates up to 30 litres per minute and if linked to the appropriate gas, oil, or LPG boiler are suitable for average to larger properties. The bottom coil must be pumped. The units look smart too, with a wipe-clean white appliance finish, and the insulation is 60mm foam injected for maximum efficiencies. Stainless steel construction offers a lightweight long life product. The stores are guaranteed for ten years, the parts for two.

Request for a quote

United Kingdom

Use these Advance Thermal Stores for the provision of fast, safe hot water provision throughout the house. The indirect pattern (TSi) Twin Coil with the integrated feed and expansion tank can be sited anywhere in the property. The lower coil can be connected to a sealed system boiler in a Y plan, thus only one pump is needed. The store remains vented, with the contents of the store used as a medium for heat transfer only. These low maintenance pre plumbed units provide flow rates up to 30 litres per minute and if linked to the appropriate gas, oil, solid fuel, biomass or other appliance (except Heat Pumps) are suitable for average to larger properties.

Request for a quote

United Kingdom

Use these Advance Thermal Stores for the provision of fast, safe hot water provision throughout the house. They work on the thermal store principle of storing central heating water and providing mains fed hot water via a powerful coil for power showering and quick bath filling. The coil is not pumped. The thermal store acts as a buffer for fast radiator heat up and boiler efficiency. The direct pattern cylinder (TSDC) without the integrated feed and expansion tank has to be fed with a remote F and E tank sited above the highest point of the radiator circuit. You need two pumps - one for the boiler to keep the store hot - controlled by the thermostat on the store, and one for the heating circuit - controlled by the room thermostat and heating programmer. These low maintenance pre plumbed units provide flow rates up to 30 litres per minute and if linked to the appropriate gas, oil, solid fuel or biomass(except Heat Pumps) are suitable for average to larger properties

Request for a quote

United Kingdom

Use these Advance Thermal Stores for the provision of fast, safe hot water provision throughout the house. The thermal store principle stores central heating water in the tank. Mains pressure hot water is created with an internal powerful coil for power showers and quick bath filling. This coil is not pumped. The thermal store acts as a buffer to reduce boiler cycling and improve efficiencies - and heats the radiators quickly. The direct pattern (TSD) single coil with integrated feed and expansion tank has to be above the radiator circuit as the water is drawn from the tank for fast heat-up. You need two pumps - one for the boiler to keep the store hot - controlled by the thermostat on the store, and one for the heating circuit - controlled by the room thermostat and heating programmer.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

United Kingdom

The Plug n Glow is a small stainless steel flow boiler with many applications. It has 22mm connections for ease of installation, a 13 amp plug fitted and can be programmed up to 20 times a day seven days a week. It can be used in a sealed system up to 3 bar pressure or in vented applications. Temperature is adjusted from 30 to 80 degrees by a calibrated dial on the front of the case or it can be controlled by an off board thermostat. There is no restriction on the number of uses of the product It can be added to an existing gas or electric central heating circuit to boost the power if an extension has been added to the house; it can be used for a small office or garage workshop heating system - it will run a couple of radiators - or a standalone underfloor system in conservatories up to 20square metres floor area. Or use it to protect plants from frost in a greenhouse, or holiday homes from freezing in winter with a frost thermostat.

Request for a quote

United Kingdom

The Advance Solar EnergyManager is a tried and tested thermal store design with an internal heat exchanger and shunt pump arrangement resulting in delivery of hot water equivalent to the volume of the tank at 43ºC. The solar version has a dedicated solar coil which reduces energy bills and reliance on fossil fuel. The solar thermal panels will contribute to heating and hot water during periods of solar gain. The shunt pump is pre fitted and wired to activate when taps or showers are turned on. The EnergyManager comes as shown above with wiring centre for installers to complete the wiring for the rest of the system. Full instructions for wiring the total system are included. At 65ºC operation the EnergyManager is perfect for underfloor or low temperature radiator circuits and offers efficiencies due to the temperature being lower than most thermal stores. As a thermal store it can reduce boiler cycling and act as a buffer for heating.

Request for a quote

United Kingdom

The Advance EnergyManager is a tried and tested design with an internal heat exchanger and shunt pump arrangement resulting in delivery of hot water equivalent to the volume of the tank at 43ºC. It works on the thermal store principle of storing primary (central heating) water and delivering mains pressure hot water through a heat exchanger. The shunt pump is pre fitted and wired to activate when taps or showers are turned on. The EnergyManager comes as shown above with wiring centre for installers to complete the wiring for the rest of the system. Full instructions for wiring the total system are included. At 65ºC operation the EnergyManager is perfect for underfloor or low temperature radiator circuits and offers efficiencies due to the temperature being lower than most thermal stores. It delivers hot water equivalent to the capacity of the store.

Request for a quote

United Kingdom

VERSOTHERM-STI Range are Storage Calorifiers are with Internal Heat Exchangers or Electrical Heaters. The Heating Capacity is designed based on the Average Hot Water Demand, with One Hour to Four Hour Recovery. Two types of immersion heaters are used: U-Tube or Electric Heaters. Both can be used as a primary heating source or backup. Immersion heating batteries can be removed for inspection and cleaning and they can also work at higher temperatures and pressures than coils found on indirect cylinders. VERSOTHERM-STI range also includes Calorifiers with Spiral Tube Heat Exchangers, which is suitable for Low Heating demand applications like- Solar Heating or Heat Pump Systems. VERSOL manufacture calorifiers using the following standard materials: Copper-Lined Steel Stainless Steel Lined Steel Stainless Steel 316L Stainless Steel 304L Glass Lined/Enamel Lined Steel

Request for a quote

United Kingdom

VERSOTHERM- STORAGE CALORIFIERS The Versol range of storage calorifiers- VERSOTHERM offers an ideal solution when a volume of domestic hot water is required. Water is heated indirectly by a primary medium via an immersion heating battery and stored in the tank. Based on the heating Capacity design, VERSOTHERM is available in 2 Range VERSOTHERM-STI (Standard Storage Calorifiers with HEX or Electric Heater) VERSOTHERM- INS (Instantaneous Heating Calorifiers) VERSOL manufacture calorifiers using the following standard materials: Copper-Lined Steel Stainless Steel Lined Steel Stainless Steel 316L Stainless Steel 304L Glass Lined/Enamel Lined Steel

Request for a quote

United Kingdom

Verified by Europages

The needs of the power generation industry include year in and year out reliability, optimum performance for maximum efficiency, and absolute on time delivery to meet plant outage schedules. All of the Jet Flow Boiler Feed Water Heaters are designed in accordance with HEI standards, TEMA and ASME codes. Jet Flow uses state of the art computer programs to perform the thermal hydraulic and mechanical design of each Feed Water Heater we fabricate. Jet Flow designs and manufactures both Low Pressure (LP) and High Pressure (HP) feed water heaters which may be installed either vertically or horizontally, depending on the plant design requirements. Each Jet Flow Feed Water Heater will contain from one to three separate heat transfer areas of zones including the Condensing, Desuperheating and Subcooling zones. Our heaters can be provided with multiple zones within the shell side Condensing Zone Included in all heaters,steam is condensed in this zone and non condensable gases are removed.

Request for a quote
Filters

Results for

Water-heaters- domestic - Import export

Number of results

12 Products